| Sign In | Join Free | My insurersguide.com | 
 | 
Brand Name : SIEMENS
Model Number : 6ES7412-2EK07-0AB0
Certification : CE
Place of Origin : GERMANY
MOQ : 1
Price : USD
Payment Terms : L/C, T/T
Supply Ability : 10PS
Delivery Time : 5-10DAYS
Packaging Details : 30*20*4
CPU : S7-400
Communication : Ethernet, Profibus, Profinet, MPI, and more
Dimensions : 290x 219 x 21mm
Memory : Up to 512 KB
Mounting : Rack-mounted
Operating temperature : 0°C to 60°C
Power supply : 24 V DC
Product name : PLC SIMATIC S7-400
Programming environment : STEP 7
Programming language : Ladder logic, Function block diagram, Structured text, Sequential function chart
Protection class : IP20
Type : Programmable Logic Controller
Weight : 0.7 kg
SIEMENS SIMATIC PLC S7-400 6ES7412-2EK07-0AB0 CPU 412-2 PN Central processing unit with
Product Name: SIEMENS SIMATIC PLC S7-400 6ES7412-2EK07-0AB0 CPU 412-2 PN
Introduction:
  The SIEMENS SIMATIC PLC S7-400 6ES7412-2EK07-0AB0 CPU 412-2 PN is a central processing unit (CPU) designed for the SIEMENS SIMATIC S7-400 series programmable logic controllers (PLCs). It is equipped with PROFINET communication capability, allowing for seamless integration into industrial networks.
Origin: Germany
Product Specifications:
  - Product Name: SIEMENS SIMATIC PLC S7-400 6ES7412-2EK07-0AB0 CPU 412-2 PN
  - CPU Type: 412-2 PN
  - Compatibility: SIEMENS SIMATIC S7-400 series
  - Number of Digital Inputs: Varies depending on configuration
  - Number of Digital Outputs: Varies depending on configuration
  - Number of Analog Inputs: Varies depending on configuration
  - Number of Analog Outputs: Varies depending on configuration
  - Communication Ports: Multiple communication interfaces (e.g., PROFINET, PROFIBUS, MPI)
  - Memory: Varies depending on configuration
  - Operating Temperature: 0 to 60°C
  - Dimensions (W x H x D): Varies depending on the module
  - Weight: Varies depending on the module
Product Features:
  - Central processing unit (CPU) for large and complex automation applications
  - Compatible with the SIEMENS SIMATIC S7-400 series
  - Supports a wide range of digital and analog inputs and outputs
  - PROFINET communication capability for seamless integration into industrial networks
  - Multiple communication interfaces for flexible connectivity (PROFINET, PROFIBUS, MPI)
  - Flexible memory configuration to accommodate specific application requirements
  - Robust construction and reliable performance for demanding industrial environments
  - Easy programming and configuration using the STEP 7 programming software
Functionality:
  - The SIMATIC PLC S7-400 6ES7412-2EK07-0AB0 CPU 412-2 PN is designed to provide high-performance control and communication capabilities for large and complex automation applications.
  - It is compatible with the SIEMENS SIMATIC S7-400 series, allowing for seamless integration with other modules and components.
  - The CPU supports a wide range of digital and analog inputs and outputs, providing flexibility for various automation requirements.
  - With its PROFINET communication capability, the CPU can easily connect to other devices and networks in industrial environments.
  - The CPU also supports additional communication interfaces such as PROFIBUS and MPI for flexible connectivity options.
  - The memory configuration can be customized to accommodate specific application requirements.
  - With its robust construction and reliable performance, the CPU is suitable for demanding industrial environments.
  - Programming and configuration can be done using the STEP 7 programming software, which offers a user-friendly interface for efficient development and maintenance.
Please note that for more detailed technical specifications and information, it is recommended to refer to the official documentation or contact Siemens directly.



| SIMATIC S7-400, CPU 412-2 PN Central processing unit with: Work memory 1 MB, (0.5 MB code; 0.5 MB data) interfaces 1st interface MPI/DP 12 Mbit/s, (X1), 2nd interface Ethernet/PROFINET (X5) | ||
| General information | ||
| Product type designation | CPU 412-2 PN | |
| HW functional status | 01 | |
| Firmware version | V7.0 | |
| Product function | ||
| ● Isochronous mode | Yes; Via PROFIBUS DP or PROFINET interface | |
| Engineering with | ||
| ● Programming package | STEP 7 V5.5 or higher with HSP 262 | |
| CiR - Configuration in RUN | ||
| CiR synchronization time, basic load | 100 ms | |
| CiR synchronization time, time per I/O byte | 30 µs | |
| Supply voltage | ||
| Rated value (DC) | Power supply via system power supply | |
| Input current | ||
| from backplane bus 5 V DC, typ. | 1.1 A | |
| from backplane bus 5 V DC, max. | 1.4 A | |
| from backplane bus 24 V DC, max. | 150 mA; 150 mA per DP interface | |
| from interface 5 V DC, max. | 90 mA; At the DP interface | |
| Power loss | ||
| Power loss, typ. | 5.5 W | |
| Power loss, max. | 7 W | |
| Memory | ||
| Type of memory | RAM | |
| Work memory | ||
| ● integrated | 1 Mbyte | |
| ● integrated (for program) | 512 kbyte | |
| ● integrated (for data) | 512 kbyte | |
| ● expandable | No | |
| Load memory | ||
| ● expandable FEPROM | Yes; with Memory Card (FLASH) | |
| ● expandable FEPROM, max. | 64 Mbyte | |
| ● integrated RAM, max. | 512 kbyte | |
| ● expandable RAM | Yes; with Memory Card (RAM) | |
| ● expandable RAM, max. | 64 Mbyte | |
| Backup | ||
| ● present | Yes | |
| ● with battery | Yes; all data | |
| ● without battery | No | |
| Battery | ||
| Backup battery | ||
| ● Backup current, typ. | 180 µA; up to 40 °C | |
| ● Backup current, max. | 850 µA | |
| ● Backup time, max. | Dealt with in the module data manual with the secondary conditions and the factors of influence | |
| ● Feeding of external backup voltage to CPU | 5 V DC to 15 V DC | |
| CPU processing times | ||
| for bit operations, typ. | 31.25 ns | |
| for word operations, typ. | 31.25 ns | |
| for fixed point arithmetic, typ. | 31.25 ns | |
| for floating point arithmetic, typ. | 62.5 ns | |
| CPU-blocks | ||
| DB | ||
| ● Number, max. | 3 000; Number range: 1 to 16000 | |
| ● Size, max. | 64 kbyte | |
| FB | ||
| ● Number, max. | 1 500; Number range: 0 to 7999 | |
| ● Size, max. | 64 kbyte | |
| FC | ||
| ● Number, max. | 1 500; Number range: 0 to 7999 | |
| ● Size, max. | 64 kbyte | |
| OB | ||
| ● Number, max. | see instruction list | |
| ● Size, max. | 64 kbyte | |
| ● Number of free cycle OBs | 1; OB 1 | |
| ● Number of time alarm OBs | 2; OB 10, 11 | |
| ● Number of delay alarm OBs | 2; OB 20, 21 | |
| ● Number of cyclic interrupt OBs | 2; OB 32, 35 (shortest cycle that can be set = 500 µs) | |
| ● Number of process alarm OBs | 2; OB 40, 41 | |
| ● Number of DPV1 alarm OBs | 3; OB 55-57 | |
| ● Number of isochronous mode OBs | 2; OB 61-62 | |
| ● Number of multicomputing OBs | 1; OB 60 | |
| ● Number of background OBs | 1; OB 90 | |
| ● Number of startup OBs | 3; OB 100-102 | |
| ● Number of asynchronous error OBs | 9; OB 80-88 | |
| ● Number of synchronous error OBs | 2; OB 121, 122 | |
| Nesting depth | ||
| ● per priority class | 24 | |
| ● additional within an error OB | 1 | |
| Counters, timers and their retentivity | ||
| S7 counter | ||
| ● Number | 2 048 | |
| Retentivity | ||
| — adjustable | Yes | |
| — preset | Z 0 to Z 7 | |
| Counting range | ||
| — lower limit | 0 | |
| — upper limit | 999 | |
| IEC counter | ||
| ● present | Yes | |
| ● Type | SFB | |
| ● Number | Unlimited (limited only by RAM capacity) | |
| S7 times | ||
| ● Number | 2 048 | |
| Retentivity | ||
| — adjustable | Yes | |
| — preset | No times retentive | |
| Time range | ||
| — lower limit | 10 ms | |
| — upper limit | 9 990 s | |
| IEC timer | ||
| ● present | Yes | |
| ● Type | SFB | |
| ● Number | Unlimited (limited only by RAM capacity) | |
| Data areas and their retentivity | ||
| Retentive data area (incl. timers, counters, flags), max. | Total working and load memory (with backup battery) | |
| Flag | ||
| ● Size, max. | 4 kbyte; Size of bit memory address area | |
| ● Retentivity available | Yes | |
| ● Retentivity preset | MB 0 to MB 15 | |
| ● Number of clock memories | 8; in 1 memory byte | |
| Local data | ||
| ● adjustable, max. | 8 kbyte | |
| ● preset | 4 kbyte | |
| Address area | ||
| I/O address area | ||
| ● Inputs | 4 kbyte | |
| ● Outputs | 4 kbyte | |
| Process image | ||
| ● Inputs, adjustable | 4 kbyte | |
| ● Outputs, adjustable | 4 kbyte | |
| ● Inputs, default | 128 byte | |
| ● Outputs, default | 128 byte | |
| ● consistent data, max. | 244 byte | |
| ● Access to consistent data in process image | Yes | |
| Subprocess images | ||
| ● Number of subprocess images, max. | 15 | |
| Digital channels | ||
| ● Inputs | 32 768 | |
| — of which central | 32 768 | |
| ● Outputs | 32 768 | |
| — of which central | 32 768 | |
| Analog channels | ||
| ● Inputs | 2 048 | |
| — of which central | 2 048 | |
| ● Outputs | 2 048 | |
| — of which central | 2 048 | |
| Hardware configuration | ||
| Number of expansion units, max. | 21 | |
| connectable OPs | 47 | |
| Multicomputing | Yes; 4 CPUs max. (with UR1 or UR2) | |
| Interface modules | ||
| ● Number of connectable IMs (total), max. | 6 | |
| ● Number of connectable IM 460s, max. | 6 | |
| ● Number of connectable IM 463s, max. | 4; IM 463-2 | |
| Number of DP masters | ||
| ● integrated | 1 | |
| ● via CP | 10; CP 443-5 Extended | |
| ● via IM 467 | 4 | |
| ● Mixed mode IM + CP permitted | No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode | |
| ● via interface module | 0 | |
| ● Number of pluggable S5 modules (via adapter capsule in central device), max. | 6 | |
| Number of IO Controllers | ||
| ● integrated | 1 | |
| ● via CP | 4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode | |
| Number of operable FMs and CPs (recommended) | ||
| ● FM | Limited by number of slots and number of connections | |
| ● CP, PtP | CP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections | |
| ● PROFIBUS and Ethernet CPs | 14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller | |
| Slots | ||
| ● required slots | 1 | |
| Time of day | ||
| Clock | ||
| ● Hardware clock (real-time) | Yes | |
| ● retentive and synchronizable | Yes | |
| ● Resolution | 1 ms | |
| ● Deviation per day (buffered), max. | 1.7 s; Power off | |
| ● Deviation per day (unbuffered), max. | 8.6 s; For power On | |
| Operating hours counter | ||
| ● Number | 16 | |
| ● Number/Number range | 0 to 15 | |
| ● Range of values | SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours | |
| ● Granularity | 1 h | |
| ● retentive | Yes | |
| Clock synchronization | ||
| ● supported | Yes | |
| ● to MPI, master | Yes | |
| ● to MPI, slave | Yes | |
| ● to DP, master | Yes | |
| ● to DP, slave | Yes | |
| ● in AS, master | Yes | |
| ● in AS, slave | Yes | |
| ● on Ethernet via NTP | Yes; As client | |
| ● to IF 964 DP | No | |
| Time difference in system when synchronizing via | ||
| ● Ethernet, max. | 10 ms | |
| ● MPI, max. | 200 ms | |
| Interfaces | ||
| Interfaces/bus type | 1 x MPI/PROFIBUS DP, 1 x PROFINET (2 ports) | |
| Number of RS 485 interfaces | 1; Combined MPI / PROFIBUS DP | |
| 1. Interface | ||
| Interface type | MPI/PROFIBUS DP | |
| Isolated | Yes | |
| Interface types | ||
| ● RS 485 | Yes | |
| ● Output current of the interface, max. | 150 mA | |
| Protocols | ||
| ● MPI | Yes | |
| ● PROFIBUS DP master | Yes | |
| ● PROFIBUS DP slave | Yes | |
| MPI | ||
| ● Number of connections | 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 | |
| ● Transmission rate, max. | 12 Mbit/s | |
| Services | ||
| — PG/OP communication | Yes | |
| — Routing | Yes | |
| — Global data communication | Yes | |
| — S7 basic communication | Yes | |
| — S7 communication | Yes | |
| — S7 communication, as client | Yes | |
| — S7 communication, as server | Yes | |
| PROFIBUS DP master | ||
| ● Number of connections, max. | 16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 | |
| ● Transmission rate, max. | 12 Mbit/s | |
| ● Number of DP slaves, max. | 32 | |
| Services | ||
| — PG/OP communication | Yes | |
| — Routing | Yes; S7 routing | |
| — Global data communication | No | |
| — S7 basic communication | Yes | |
| — S7 communication | Yes | |
| — S7 communication, as client | Yes | |
| — S7 communication, as server | Yes | |
| — Equidistance | Yes | |
| — Isochronous mode | Yes | |
| — SYNC/FREEZE | Yes | |
| — Activation/deactivation of DP slaves | Yes | |
| — Direct data exchange (slave-to-slave communication) | Yes | |
| — DPV1 | Yes | |
| Address area | ||
| — Inputs, max. | 2 kbyte | |
| — Outputs, max. | 2 kbyte | |
| User data per DP slave | ||
| — User data per DP slave, max. | 244 byte | |
| — Inputs, max. | 244 byte | |
| — Outputs, max. | 244 byte | |
| — Slots, max. | 244 | |
| — per slot, max. | 128 byte | |
| PROFIBUS DP slave | ||
| ● Number of connections | 16 | |
| ● GSD file | http://support.automation.siemens.com/WW/view/en/113652 | |
| ● Transmission rate, max. | 12 Mbit/s | |
| ● automatic baud rate search | No | |
| ● Address area, max. | 32; Virtual slots | |
| ● User data per address area, max. | 32 byte | |
| — of which consistent, max. | 32 byte | |
| Services | ||
| — PG/OP communication | Yes; with interface active | |
| — Routing | Yes; with interface active | |
| — Global data communication | No | |
| — S7 basic communication | No | |
| — S7 communication | Yes | |
| — S7 communication, as client | Yes | |
| — S7 communication, as server | Yes | |
| — Direct data exchange (slave-to-slave communication) | No | |
| — DPV1 | No | |
| Transfer memory | ||
| — Inputs | 244 byte | |
| — Outputs | 244 byte | |
| 2. Interface | ||
| Interface type | PROFINET | |
| Isolated | Yes | |
| automatic detection of transmission rate | Yes; Autosensing | |
| Autonegotiation | Yes | |
| Autocrossing | Yes | |
| Change of IP address at runtime, supported | Yes; Assignment by higher-level IO-Controller or by the user program with SFB104 "IP_CONF" | |
| Interface types | ||
| ● RJ 45 (Ethernet) | Yes | |
| ● Number of ports | 2 | |
| ● integrated switch | Yes | |
| Protocols | ||
| ● PROFINET IO Controller | Yes | |
| ● PROFINET IO Device | Yes | |
| ● PROFINET CBA | Yes | |
| ● PROFIBUS DP master | No | |
| ● PROFIBUS DP slave | No | |
| ● Open IE communication | Yes | |
| ● Web server | Yes | |
| ● Point-to-point connection | No | |
| ● Media redundancy | Yes | |
| PROFINET IO Controller | ||
| ● Transmission rate, max. | 100 Mbit/s | |
| Services | ||
| — PG/OP communication | Yes | |
| — S7 communication | Yes | |
| — Isochronous mode | Yes; Only with IRT and the High Performance option | |
| — Shared device | Yes | |
| — Prioritized startup | Yes | |
| — Number of IO devices with prioritized startup, max. | 32 | |
| — Number of connectable IO Devices, max. | 256 | |
| — Of which IO devices with IRT, max. | 64 | |
| — of which in line, max. | 64 | |
| — Number of IO Devices with IRT and the option "high flexibility" | 256 | |
| — of which in line, max. | 61 | |
| — Number of connectable IO Devices for RT, max. | 256 | |
| — of which in line, max. | 256 | |
| — Activation/deactivation of IO Devices | Yes | |
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 | |
| — IO Devices changing during operation (partner ports), supported | Yes | |
| — Number of IO Devices per tool, max. | 8; 8 parallel calls of the SFC 12 "D_ACT_DP" possible per line. Max. 32 IO Devices changing during operation (partner ports) are supported | |
| — Device replacement without swap medium | Yes | |
| — Send cycles | 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame | |
| — Updating time | 250 µs to 512 ms; minimum value depends on preset communication share for PROFINET IO, on the number of IO Devices and on the amount of configured user data, see PROFINET system description | |
| Address area | ||
| — Inputs, max. | 4 kbyte | |
| — Outputs, max. | 4 kbyte | |
| — User data consistency, max. | 1 024 byte | |
| PROFINET IO Device | ||
| Services | ||
| — PG/OP communication | Yes | |
| — S7 communication | Yes | |
| — Isochronous mode | No | |
| — IRT | Yes | |
| — Prioritized startup | Yes | |
| — Shared device | Yes | |
| — Number of IO Controllers with shared device, max. | 2 | |
| Transfer memory | ||
| — Inputs, max. | 1 440 byte; Per IO Controller with shared device | |
| — Outputs, max. | 1 440 byte; Per IO Controller with shared device | |
| Submodules | ||
| — Number, max. | 64 | |
| — User data per submodule, max. | 1 024 byte | |
| PROFINET CBA | ||
| ● acyclic transmission | Yes | |
| ● cyclic transmission | Yes | |
| Open IE communication | ||
| ● Number of connections, max. | 46 | |
| ● Local port numbers used at the system end | 0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535 | |
| ● Keep-alive function, supported | Yes | |
| Protocols | ||
| Redundancy mode | ||
| Media redundancy | ||
| — Switchover time on line break, typ. | 200 ms | |
| — Number of stations in the ring, max. | 50 | |
| SIMATIC communication | ||
| ● S7 routing | Yes | |
| Open IE communication | ||
| ● TCP/IP | Yes; via integrated PROFINET interface and loadable FBs | |
| — Number of connections, max. | 46 | |
| — Data length, max. | 32 kbyte | |
| — several passive connections per port, supported | Yes | |
| ● ISO-on-TCP (RFC1006) | Yes; Via integrated PROFINET interface or CP 443-1 Adv. and loadable FBs | |
| — Number of connections, max. | 46 | |
| — Data length, max. | 32 kbyte; 1 452 bytes via CP 443-1 Adv. | |
| ● UDP | Yes; via integrated PROFINET interface and loadable FBs | |
| — Number of connections, max. | 46 | |
| — Data length, max. | 1 472 byte | |
| Web server | ||
| ● supported | Yes | |
| ● User-defined websites | Yes | |
| ● Number of HTTP clients | 5 | |
| Isochronous mode | ||
| Equidistance | Yes | |
| Number of DP masters with isochronous mode | 1 | |
| User data per isochronous slave, max. | 244 byte | |
| shortest clock pulse | 1.5 ms; 0.5 ms without use of SFC 126, 127 | |
| max. cycle | 32 ms | |
| communication functions / header | ||
| PG/OP communication | Yes | |
| ● Number of connectable OPs without message processing | 47 | |
| ● Number of connectable OPs with message processing | 47; When using Alarm_S/SQ and Alarm_D/DQ | |
| Data record routing | Yes | |
| Global data communication | ||
| ● supported | Yes | |
| ● Number of GD loops, max. | 8 | |
| ● Number of GD packets, transmitter, max. | 8 | |
| ● Number of GD packets, receiver, max. | 16 | |
| ● Size of GD packets, max. | 54 byte | |
| ● Size of GD packet (of which consistent), max. | 1 variable | |
| S7 basic communication | ||
| ● communication function / S7 basic communication | Yes | |
| ● User data per job, max. | 76 byte | |
| ● User data per job (of which consistent), max. | 1 variable | |
| S7 communication | ||
| ● supported | Yes | |
| ● as server | Yes | |
| ● as client | Yes | |
| ● User data per job, max. | 64 kbyte | |
| ● User data per job (of which consistent), max. | 462 byte; 1 variable | |
| S5 compatible communication | ||
| ● supported | Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 | |
| ● User data per job, max. | 8 kbyte | |
| ● User data per job (of which consistent), max. | 240 byte | |
| ● Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. | 24/24 | |
| Standard communication (FMS) | ||
| ● supported | Yes; Via CP and loadable FB | |
| communication functions / PROFINET CBA (with set target communication load) / header | ||
| ● Setpoint for the CPU communication load | 20 % | |
| ● Number of remote interconnection partners | 32 | |
| ● Number of functions, master/slave | 150 | |
| ● Total of all master/slave connections | 4 500 | |
| ● Data length of all incoming connections master/slave, max. | 45 000 byte | |
| ● Data length of all outgoing connections master/slave, max. | 45 000 byte | |
| ● Number of device-internal and PROFIBUS interconnections | 1 000 | |
| ● Data length of device-internal und PROFIBUS interconnections, max. | 16 000 byte | |
| ● Data length per connection, max. | 2 000 byte | |
| performance data / PROFINET CBA / remote interconnection / with acyclic transfer / header | ||
| — Sampling interval, min. | 200 ms; Depending on preset communication load, number of interconnections and data length used | |
| — Number of incoming interconnections | 250 | |
| — Number of outgoing interconnections | 250 | |
| — Data length of all incoming interconnections, max. | 8 000 byte | |
| — Data length of all outgoing interconnections, max. | 8 000 byte | |
| — data volume / as user data for remote interconnections / in the case of acyclic transmission / with PROFINET CBA / per connection / maximum | 2 000 byte | |
| performance data / PROFINET CBA / remote interconnection / with cyclic transfer / header | ||
| — Transmission frequency: Transmission interval, min. | 1 ms; Depending on preset communication load, number of interconnections and data length used | |
| — number of remote connections to input variables / with PROFINET CBA / with cyclic transfer / maximum | 300 | |
| — number of remote connections to output variables / with cyclical transfer / with PROFINET CBA / maximum | 300 | |
| — data volume / as user data for remote interconnections with input variables / with cyclical transfer / with PROFINET CBA / maximum | 4 800 byte | |
| — data volume / as user data for remote interconnections with output variables / with cyclical transfer / with PROFINET CBA / maximum | 4 800 byte | |
| — data volume / as user data for remote interconnections / with cyclical transfer / with PROFINET CBA / per connection / maximum | 450 byte | |
| performance data / PROFINET CBA / HMI variables via PROFINET / acyclic / header | ||
| — Number of stations that can log on for HMI variables (PN OPC/iMap) | 2x PN OPC/1x iMap | |
| — HMI variable updating | 500 ms | |
| — Number of HMI variables | 1 000 | |
| — Data length of all HMI variables, max. | 32 000 byte | |
| performance data / PROFINET CBA / PROFIBUS proxy functionality / header | ||
| — supported | Yes; 32 PROFIBUS slaves max. connectable | |
| — Data length per connection, max. | 240 byte; Slave-dependent | |
| Number of connections | ||
| ● overall | 48 | |
| ● usable for PG communication | 47 | |
| — reserved for PG communication | 1 | |
| — adjustable for PG communication, max. | 0 | |
| ● usable for OP communication | 47 | |
| — reserved for OP communication | 1 | |
| — adjustable for OP communication, max. | 0 | |
| ● usable for S7 basic communication | 46 | |
| — reserved for S7 basic communication | 0 | |
| — adjustable for S7 basic communication, max. | 0 | |
| ● usable for S7 communication | 46 | |
| — reserved for S7 communication | 0 | |
| — adjustable for S7 communication, max. | 0 | |
| ● usable for routing | 23 | |
| — reserved for routing | 0 | |
| — adjustable for routing, max. | 0 | |
| S7 message functions | ||
| Number of login stations for message functions, max. | 47; Max. 47 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC) | |
| Symbol-related messages | Yes | |
| SCAN procedure | Yes | |
| Program alarms | Yes | |
| Process diagnostic messages | Yes | |
| simultaneously active Alarm-S blocks, max. | 250; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks | |
| Alarm 8-blocks | Yes | |
| ● Number of instances for alarm 8 and S7 communication blocks, max. | 300 | |
| ● preset, max. | 150 | |
| Process control messages | Yes | |
| Number of archives that can log on simultaneously (SFB 37 AR_SEND) | 4 | |
| Number of messages | ||
| ● overall, max. | 256 | |
| ● in 100 ms grid, max. | 0 | |
| ● in 500 ms grid, max. | 256 | |
| ● in 1000 ms grid, max. | 256 | |
| Number of additional values | ||
| ● with 100 ms grid, max. | 0 | |
| ● with 500, 1000 ms grid, max. | 1 | |
| Test commissioning functions | ||
| Status block | Yes; Up to 16 simultaneously | |
| Single step | Yes | |
| Number of breakpoints | 16 | |
| Status/control | ||
| ● Status/control variable | Yes; Up to 16 variable tables | |
| ● Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters | |
| ● Number of variables, max. | 70; Status/control | |
| Forcing | ||
| ● Forcing | Yes | |
| ● Forcing, variables | Inputs/outputs, bit memories, distributed I/Os | |
| ● Number of variables, max. | 64 | |
| Diagnostic buffer | ||
| ● present | Yes | |
| ● Number of entries, max. | 3 200 | |
| — adjustable | Yes | |
| — preset | 120 | |
| Service data | ||
| ● can be read out | Yes | |
| Standards, approvals, certificates | ||
| CE mark | Yes | |
| CSA approval | Yes | |
| UL approval | Yes | |
| cULus | Yes | |
| FM approval | Yes | |
| RCM (formerly C-TICK) | Yes | |
| KC approval | Yes | |
| EAC (formerly Gost-R) | Yes | |
| Use in hazardous areas | ||
| ● ATEX | ATEX II 3G Ex nA IIC T4 Gc | |
| Ambient conditions | ||
| Ambient temperature during operation | ||
| ● min. | 0 °C | |
| ● max. | 60 °C | |
| configuration / header | ||
| Configuration software | ||
| ● STEP 7 | Yes | |
| configuration / programming / header | ||
| ● Command set | see instruction list | |
| ● Nesting levels | 7 | |
| ● Access to consistent data in process image | Yes | |
| ● System functions (SFC) | see instruction list | |
| ● System function blocks (SFB) | see instruction list | |
| Programming language | ||
| — LAD | Yes | |
| — FBD | Yes | |
| — STL | Yes | |
| — SCL | Yes | |
| — CFC | Yes | |
| — GRAPH | Yes | |
| — HiGraph® | Yes | |
| configuration / programming / number of simultaneously active SFC / header | ||
| — DPSYC_FR | 2; SFC 11; per interface | |
| — D_ACT_DP | 8; SFC 12; per interface | |
| — RD_REC | 8; SFC 59; per interface | |
| — WR_REC | 8; SFC 58; per interface | |
| — WR_PARM | 8; SFC 55; per interface | |
| — PARM_MOD | 1; SFC 57; per interface | |
| — WR_DPARM | 2; SFC 56; per interface | |
| — DPNRM_DG | 8; SFC 13; per interface | |
| — RDSYSST | 8; SFC 51 | |
| — DP_TOPOL | 1; SFC 103; per interface | |
| configuration / programming / number of simultaneously active SFB / header | ||
| — RDREC | 8; SFB 52; per interface, but not more than 32 across all external interfaces | |
| — WRREC | 8; SFB 53; per interface, but not more than 32 across all external interfaces | |
| Know-how protection | ||
| ● User program protection/password protection | Yes | |
| ● Block encryption | Yes; With S7 block Privacy | |
| Dimensions | ||
| Width | 25 mm | |
| Height | 290 mm | |
| Depth | 219 mm | |
| Weights | ||
| Weight, approx. | 750 g | |
|   | 
| SIEMENS SIMATIC PLC S7-400 6ES7412-2EK07-0AB0 CPU 412-2 PN Central processing unit with Images | 
 SIEMESN SIMATIC PLC S7-400 MODULE AUTOMATION SYSTEM
                                                                                    
                        
                        
                        
                                                            SIEMESN SIMATIC PLC S7-400 MODULE AUTOMATION SYSTEM
                                                    
                        
                     SIEMENS 6ES7403-1JA11-0AA0 S7-400, ER2 EXPANSION RACK ALU, 9 SLOTS
                                                                                    
                        
                        
                        
                                                            SIEMENS 6ES7403-1JA11-0AA0 S7-400, ER2 EXPANSION RACK ALU, 9 SLOTS
                                                    
                        
                     SIEMENS 6ES7403-1TA00-0AA0 SIMATIC S7-400, ER1 EXP. RACK, WITH 18 SLOTS,F.
                                                                                    
                        
                        
                        
                                                            SIEMENS 6ES7403-1TA00-0AA0 SIMATIC S7-400, ER1 EXP. RACK, WITH 18 SLOTS,F.
                                                    
                        
                     SIMATIC S7-400, extension rack ER1 with 18 slots, only for signal modules 2
                                                                                    
                        
                        
                        
                                                            SIMATIC S7-400, extension rack ER1 with 18 slots, only for signal modules 2
                                                    
                        
                     SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1
                                                                                    
                        
                        
                        
                                                            SIEMENS SIMATIC PLC S7-400 6ES7412-1XJ05-0AB0 CPU 412-1
                                                    
                        
                     SIEMENS SIMATIC PLC S7-400 6ES7414-3FM07-0AB0 CPU414F-3 PN/DP Central processing
                                                                                    
                        
                        
                        
                                                            SIEMENS SIMATIC PLC S7-400 6ES7414-3FM07-0AB0 CPU414F-3 PN/DP Central processing
                                                    
                        
                     SIEMENS SIMATIC PLC S7-400 6ES7416-2XN05-0AB0 CPU 416-2 Central processing unit
                                                                                    
                        
                        
                        
                                                            SIEMENS SIMATIC PLC S7-400 6ES7416-2XN05-0AB0 CPU 416-2 Central processing unit
                                                    
                        
                     SIEMENS SIMATIC PLC S7-400 6ES7416-3ES06-0AB0 CPU 416-3 PN/DP Central processing
                                                                                    
                        
                        
                        
                                                            SIEMENS SIMATIC PLC S7-400 6ES7416-3ES06-0AB0 CPU 416-3 PN/DP Central processing
                                                    
                        
                     SIEMENS SIMATIC PLC S7-400 6ES7416-2FN05-0AB0 CPU416F-2 Central processing unit
                                                                                    
                        
                        
                        
                                                            SIEMENS SIMATIC PLC S7-400 6ES7416-2FN05-0AB0 CPU416F-2 Central processing unit
                                                    
                        
                     SIEMENS SIMATIC PLC S7-400 6ES7416-3XR05-0AB0 CPU416-3 Central processing unit
                                                                                    
                        
                        
                        
                                                            SIEMENS SIMATIC PLC S7-400 6ES7416-3XR05-0AB0 CPU416-3 Central processing unit